The duct air leakage testing equipment shall be attached to the largest return in the system or to the air handler.

Hvac duct leakage test results.

How to test duct leakage b i basic. Irc 2015 n1103 3 4 allows the following duct leakage. If specimen fails to meet allotted leakage level the contractor shall modify to bring it into compliance and shall retest it until acceptable leakage is demonstrated. 25 pa across the system including manufacturer s air handler enclosure all registers taped or otherwise sealed post construction test.

Leakage class can be calculated using equation 3 but needs to be specified if duct air leakage tests are required. Table 3 is an abridged version of appendix e from the smacna hvac duct leak test manual that quantifi es the amount of leakage by pressure for each duct class. Rough in test less than 4 cfm per 100 sq ft which for my house is about 160 cfm if the air handler is included in the leakage test. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating ventilating and air conditioning hvac ductwork.

Ducts shall be pressure tested to determine air leakage by either of the following. Crisis spiral ductwork with leakage rates of less than 1 percent may again have to be considered for pressures of 1 inch to 10 inch wg. Duct leakage test system consists of duct leakage test system consists of. Th e engineer can use this table.

They did not test the drier vent ducts or erv ducts because their leakage rate would be too small to measure they said. The instrument provides step by step test configuration and automated leakage testing based on the smacna hvac air duct leakage test manual and is accurate to 2 5 of reading. Duct leakage test results rough in test air handler not installed total leakage 4 cfm per 100 ft2 of conditioned floor area tested at a pressure differential 25pa 0 1 in w g across roughed in system all register boots taped or otherwise sealed. Block if present the ventilation air duct connected to the conditioning system.

Total leakage measured with a pressure differential of 0 1 inch w g. Leakage test procedures shall follow the outlines and classifications in the smacna hvac duct leakage test manual. 1 blower with speed control vfd to generate range of pressure flowrange of pressure flow. Ashrae 90 1 recommends only testing ductwork rated 3 in h 2 don t test flex duct.

Though built tough with an on board powerful motor the dalt 6900 is very easy to transport on its pneumatic tires and leaves little to no footprint on the job site. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

Leakage Test Form Fill Online Printable Fillable Blank Pdffiller

Leakage Test Form Fill Online Printable Fillable Blank Pdffiller

Https Www Smacna Org Docs Default Source Technical Resources Hvac Duct Air Leakage 9 12 19 Pdf Sfvrsn Cba0c8a5 0

Https Www Smacna Org Docs Default Source Technical Resources Hvac Duct Air Leakage 9 12 19 Pdf Sfvrsn Cba0c8a5 0

Nc Residential Building Code Energy Updates Carolina Country

Nc Residential Building Code Energy Updates Carolina Country

Duct Leakage Testing Airtight Energy Inspections

Duct Leakage Testing Airtight Energy Inspections

Source : pinterest.com